4150 & 4200 TapeStation Instrument

The Agilent 4200 TapeStation system offers automated sample processing for quick and reliable sample quality control within any Next Generation Sequencing (NGS), microarray (aCGH) or quantitative PCR (qPCR) workflow.

The Agilent TapeStation system is an automated electrophoresis solution for the sample quality control of DNA and RNA samples. The system integrates an instrument, data processing software, reagents, and ScreenTape devices specific for DNA and RNA. It is suitable to analyze size, quantity, and integrity of your samples.

A complete solution for end-to-end electrophoretic quality control of DNA and RNA samples.

Details

Category:
Electrophoresis

Manufacture:
Agilent

  • Simplify your workflow – No system setup procedures are required
  • Fast analysis – 1–2 minutes per sample, or less than 20 minutes for 16 samples (4150 TapeStation) and 90 minutes for 96 samples (4200 TapeStation)
  • Full flexibility – 16-tube strips or 96-well microtiter plates (4200 TapeStation only)
  • Low sample need – Requires only 1–2 μL of precious samples per run
  • Zero carryover – In addition to individual filtered loading tips each samples is analyzed in a discrete ScreenTape lane
  • Protect sample performance – Avoid sample evaporation by covering 96-well microtiter plates with foil
  • Small footprint – Save valuable bench space in lab with a compact system offering the complete sample QC solution
  • Maximium efficiency – Improved support features including TapeStation Test Tape for straight forward hardware diagnosis

A complete solution for complete success

Agilent provides a complete solution. Each system configuration includes:

  • An Agilent 4150 or 4200 TapeStation instrument (for RNA and DNA analysis)
  • A laptop with Agilent TapeStation software
  • Accessories (Tube Strip Holder, Tip Waste Bucket, ScreenTape Rack, USB cable)
  • Consumables (96-well plates and foil seals (4200 TapeStation only), tube strips, loading tips, TapeStation Test Tape)
  • User information (ScreenTape Assay Quick Start Guides and User Guide USB flash drive)

 

ScreenTape Technology for Confident DNA and RNA Analysis

DNA analysis

  • DNA sizing and quantification in the range 35 bp to 60 kbp and 5 pg/µL to 100 ng/µL
  • DNA Integrity Number (DIN) provided by the Genomic DNA ScreenTape assay for unambiguous DNA integrity assessment

RNA analysis

  • RNA sizing and quantifi cation in the range 100 to 6000 nt and 100 pg/µL to 500 ng/µL
  • RNA Integrity Number equivalent (RINe) feature for unambiguous RNA integrity assessment
4150 TapeStation Instrument
Weight17.8 kg (39.2lb)
Dimensions (w × d × h)254 x 510 x 415 mm (9.6 x 20.1 x 16.3 inches)
Line voltage100 – 240 V AC
Line frequency50 – 60 Hz
Power consumption50 VA
4200 TapeStation System
Weight17.8 kg
Dimensions (w x d x h)254 x 510 x 415 mm
Line voltage100-240 V AC
Line frequency50-60 Hz
Power consumption50 VA
Equipments/ItemsSpecificationsCatalog
D1000 ScreenTapeD1000 ScreenTape For the analysis of DNA from 35 to 1000 bp. Includes 7 ScreenTape. For 112 Samples5067-5582
D1000 ReagentsD1000 Reagents For the analysis of DNA from 35 to 1000 bp. Includes ladder and sample buffer. For 112 Samples5067-5583
High Sensitivity D1000 ScreenTapeHigh Sensitivity D1000 ScreenTape For the analysis of DNA from 35 to 1000 bp. Includes 7 ScreenTape. For 112 Samples5067-5584
High Sensitivity D1000 ReagentsHigh Sensitivity D1000 Reagents For the analysis of DNA from 35 to 1000 bp. Includes ladder and sample buffer. For 112 Samples5067-5585
D5000 ScreenTapeD5000 ScreenTape For the analysis of DNA from 100 to 5000 bp. Includes 7 ScreenTape devices. For 105 Samples5067-5588
D5000 ReagentsD5000 Reagents For the analysis of DNA from 100 to 5000 bp. Includes ladder and sample buffer.. For 105 Samples5067-5589
High Sensitivity D5000 ScreenTapeHigh Sensitivity D5000 ScreenTape For the analysis of DNA from 100 to 5000 bp. Includes 7 ScreenTape devices. For 105 Samples5067-5592
High Sensitivity D5000 ReagentsHigh Sensitivity D5000 Reagents For the analysis of DNA from 100 to 5000 bp. Includes ladder and sample buffer.. For 105 Samples5067-5593
Genomic DNA ScreenTapeFor the analysis of genomic DNA from 200 to > 60,000 bp. Includes 7 ScreenTape. For 105 Samples5067-5365
Genomic DNA ReagentsFor the analysis of genomic DNA from 200 to > 60,000 bp. Includes ladder and sample buffer. For 105 Samples5067-5366
RNA ScreenTapeFor the analysis of total RNA from 25 to 500ng/µL. Includes 7 ScreenTape. For 112 Samples5067-5576
RNA ScreenTape Sample BufferFor use with the RNA ScreenTape assay. For 112 Samples5067-5577
RNA ScreenTape LadderRNA ladder for use with the RNA ScreenTape assay. 10 µL5067-5578
High Sensitivity RNA ScreenTapeFor the analysis of total RNA from 500 to 10,000 pg/µL. Includes 7 ScreenTape. For 112 Samples5067-5579
High Sensitivity RNA ScreenTape Sample BufferFor use with the High Sensitivity RNA ScreenTape assay. For 112 Samples5067-5580
High Sensitivity RNA ScreenTape LadderRNA ladder for use with the High Sensitivity RNA ScreenTape assay (dilute to 20µL with RNase free water). 10 µL5067-5581
Loading Tips, 1 PkFor use with Agilent 4200 TapeStation system. 1 Pk contains 112 tips.5067-5598
Loading Tips, 10 PkFor use with Agilent 4200 TapeStation system. 1 Pk contains 10x 112 tips.5067-5599
Optical tube strips (8x Strip)For use with the Agilent TapeStation systems. Also for use with the Agilent Mx3000P & Mx3005P QPCR Systems. Box of 120401428
Optical tube strip caps (8x strip)For use with the Agilent TapeStation systems. Also for use with the Agilent Mx3000P & Mx3005P QPCR Systems. Box of 121401425
96-Well Plate Foil SealFor use with Agilent TapeStation systems. Pack of 100 foils5067-5154
96-Well Sample Plates96-well Sample Plates For TapeStation instrument.5067-5150